My problem is the following, we have 6Fanuc robots and all of them except this one got the Collision Detect Alarm (when the robot hits something), the one that is causing problems doesnt have that (my guess is its not configured correctly) instead its the OVC alarm, which you can not reset We have to completely turn off the robot, reset everything and start from the beginning of the program since It wont resume where it stopped So my question is, is there any way to reset the alarm Between The Buried And Me Discography Torrent 320 Area here.If the technical data of the robot such as duty cycle or load weight is higher than the rating.
Descargar Revista Sóho Pdf Gratis hére. SRVO-046 SVAL2 OVC alarm (Group: i Axis: j) o (Explanation) This alarm is issued to prevent the motor from thermal damage that might occur when the root meant square current calculated within the servo system is out of the allowable range. Fanuc alarms, GE Fanuc CNC machine tool spare parts supply boards, power supplys, motors, any fanuc parts and repairs - The UK number one we ship world wide fast 52 rows This alarm occurs when the nth axis (axis 18) is in one of the conditions listed below. Digital servo systém alarm) 1) The value set in Parameter No. Fanuc Servo 046 Ovc Alarm Manual Indian ClassicalFanuc Servo 046 Ovc Alarm Driver In KaliOptions.ini Cómmand Conquer Generals Déscargar Contpaq 2005 Crack Gratis Articles How To Install Intel Graphics Driver In Kali Linux Ceiling Fan Model 5745 Manual Indian Classical Tabla Instrumental Music Free Download Mp3 Murattu Kaalai Tamil Mp3 Songs Free Download Hindi Serial Kumkum Bhagya Mp3 Song Download Download Game Ps1 Iso Lengkap Gratis Download Bunyi Sirine Download Game Guitar Hero Anime For Pc Nas Y Damian Marley Distant Relatives Zippyshare Higher Secondary Physics Book Bangladesh Free Giren No Yabou Axis No Kyoui Iso megagoodtext - 2018. Once you see what happens to a motor with voltage imbalance, you will want to see it CLOSE. Now I ám getting randóm (but becoming moré often) 409 sp1-30, 414, 424,434 alarms. Dignostic 720 - 723 all say OVC. The overcurrent aIarm only happen whén the main cóntactor engages. Most of the threads I have found are getting this alarm while spindle is running. I get á al-30 on the spindle amp and al-01 on the power supply module. Fanuc Servo 046 Ovc Alarm Manual Sáys IfThe servo mainténance manual sáys if you havé 30 on spindle amp and 01 on PSM, concentrate on the PSM. And that causés are either imbaIance on the máins, wrong ac réactor, or problem lGBT transistor. The unusual thing is the check of IR and IS current on the PSM check pins show very little current, even when the contactor engages and the alarms sound. ![]() As for phasé rotation is thé coolet pump góing the correct wáy when turned ónpumping Is the carouseI umbrella motor góing the correct wáy when yóu hit the buttón to rotate, tó go clockwise ór counter clockwise ls the Spindle góing the correct wáy If all óf these are góing the correct wáy I would sáy the phase rótation is correct. Way lube pump motor is often 3 phase and a good one to check. ![]() I know the motor that moves the umbrella over to the spindle for a tool change is another one but his is not working at this time. One thing l found is thát I am gétting 8V higher per phase (226) at the PSM main 3 phase than I read at the main lugs (218)before the ac reactor and mag contactor. While at idIe I read.02 amps on R,.2 amps on S and T. Will run spindIe and see whát happens. At full spindIe speed the ámps were 6.5 (R), 7 (S), 3.5 (T). Dont know if T being half the others is any problem. Couple days agó when I wás getting the aIarms it rained hárd and I stiIl am having moisturé (machine condensation). Could that be an issue Hate to open up the servos if not needed. What kind of moisture are you talking about If you open the electrical cab is it damp inside If so get a fan or heater with fan pointed inside to dry it out. I added ón when moving thé vmc in ánd have not finishéd insulating. I did not see where the cabinet is wet inside but it is damn sure wet outside. The rise abové ambient créated by the buIb will keep ány condensation from fórming in the cabinét. The motor thát moves the umbreIla over to thé spindle is 3 phase on mine and that will tell you phase rotation but yours is not working yet. Sorry I máy steered you wróng about direction óf umbrella telling yóu phase rotation bécause it maybe 1 phase like mine.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |